Code |
Sample Environment |
Performance |
Quantity |
Instruments on which apparatus can be used |
|
CF-1 CF-2 CF-3 |
Cryofurnaces - general use (CF-1 has gas loading capabilities)
|
5K - 750K |
3 |
Echidna and Wombat (Powder Diffraction) |
|
CF-4 |
|
3.5K-300K |
1 |
Echidna and Wombat (Powder Diffraction) |
| CF-5 | Cryocooler for the Eulerian Cradles |
10K-300K |
1 |
Echidna and Wombat (Powder Diffraction) Pelican (Time-of-Flight Polarisation Analysis Spectrometer) Taipan and Sika (3-Axis) |
|
CF-6 |
Cryofurnace- reflectometer/SANS
|
10K-600K |
1 |
Quokka (SANS) |
| CF-7 CF-8 |
Top Loading Cryofurnaces |
4K-700K |
2 |
Echidna and Wombat (Powder Diffraction) Pelican (Time-of-Flight Polarisation Analysis Spectrometer) Taipan and Sika (3-Axis) |
|
OC-1 OC-2 |
|
|
2 |
Echidna and Wombat (Powder Diffraction) |
| OS-1 | 3He One shot fridge |
0.3K-80K |
1 |
Echidna and Wombat (Powder Diffraction) Quokka (SANS) Taipan and Sika (3-Axis) Kowari (Strain Scanner) Pelican (Time-of-Flight Polarisation Analysis Spectrometer) |
|
TB-1 TB-2 TB-3 |
|
-50C-250oC |
3 |
Quokka (SANS) |
|
F-1 |
20C-1800oC |
1 |
Echidna and Wombat (Powder Diffraction) Taipan (3-Axis). | |
|
F-2 |
20C-1100oC |
1 |
Echidna and Wombat (Powder Diffraction) | |
|
F-3 |
In Situ Reaction Chamber (Controlled Gas Furnace) (available February 2010) |
20C-1500C |
1 |
Echidna and Wombat (Powder Diffraction) |
|
F-4 |
1000C Air Furnace for the Horizontal Load Frame
|
20C-1000C |
1 |
Kowari (Strain Scanner) |
|
P-1 |
(available April 2010) |
200kN |
1 |
Echidna and Wombat (Powder Diffraction) |
|
P-2 |
|
100kN (tension or compression) |
1 |
Kowari (Strain Scanner) |
|
P-3 |
130 Tonne VX-5 Paris Edinburgh High Presure Cell
|
2GPa |
1 |
Echidna and Wombat (Powder Diffraction) |
|
P-4 |
Pressure Cells rated from 15 bar to 170 bar |
170 bar |
4 |
Echidna and Wombat (Powder Diffraction) Taipan and Sika (3-Axis) Pelican (Time-of-Flight Polarisation Analysis Spectrometer). |
|
VM-1 |
B < 8T; T=4.2-300K |
1 |
Echidna and Wombat (Powder Diffraction) | |
|
HM-1 |
|
B < 5T; 4K-300K |
1 |
Quokka (SANS) |
| HM-2 | Wet horizontal magnet |
B < 11T, 0.3K-300K |
1 |
Quokka (SANS) |
| HM-3 | Horizontal Electromagnet |
B=1T, 5K-300K |
1 |
Platypus |
| RQ-1 | Rapid Heat and Quench Cell |
100K-700K |
1 |
Quokka (SANS) |
|
RH-1 |
(available February 2010) |
|
1 |
Quokka (SANS) |
|
SL-1 |
|
1 |
Platypus (Reflectometer) | |
|
LF-1 LF-2 |
|
|
2 |
Platypus (Reflectometer) |
|
SC-1 |
SANS thermostat sample holders (ten position) (available April 2010) |
20C-300oC |
1 |
Quokka (SANS) |
|
SC-2 |
Sample changer-SANS (twenty position)
|
|
1 |
Quokka (SANS) |
|
SC-3 |
Sealed multiple troughs (five position) |
|
1 |
Platypus (Reflectometer) |
|
SC-4 |
Sample changer-powders (one hundred position)
|
|
1 |
Echidna and Wombat (Powder Diffraction) |
|
EC-1 EC-2 |
|
|
2 |
Echidna and Wombat (Powder Diffraction) |
| SP-1 | Syringe pump |
0.000073 mL/hr - 2100mL/hr |
1 |
Reflectometer |
| SF-1 | Stopped Flow Mixing Cell |
0.01ml |
1 |
Quokka |
| AC-1 | AC Impedence Spectrometer (available September 09) |
10kOhm-100MOhm |
1 |
Platypus (Reflectometer) |
In general, the desired equipment (or desired range of Temperature, stress, magnetic field, etc.) should be specified in the original experiment proposal, and the sample environment equipment should be booked at the same time as the instrument booking.
|
Mr Scott Olsen |
Mr Gene Davidson |
Mr Merv Perry |