Code |
Sample Environment |
(NB: temp. range approx. only - dependant on sample and setup)
|
Quantity |
Instruments on which apparatus can be used |
|
CF-1 |
Cryofurnaces (has gas loading capabilities) |
|
1 |
Echidna and Wombat (Powder Diffraction) |
|
CF-4 |
|
3.5K-300K |
1 |
Echidna and Wombat (Powder Diffraction) |
| CF-5 | Cryocooler for the Eulerian Cradles |
10K-300K |
1 |
Echidna and Wombat (Powder Diffraction) Taipan (3-Axis) |
|
CF-6 |
Cryofurnace- reflectometer/SANS
|
10K-600K |
1 |
Quokka (SANS) |
|
CF-7 |
|
4K-450K
|
1 1 |
|
|
OC-1 OC-2 TL-1 TL-5 |
Liquid Helium Cooled Orange Cryostat Top Loading Cryofurnace gas loading sample sticks |
2K-300K
4K-700K 2K-300K |
2
|
Echidna and Wombat (Powder Diffraction) For use in CF-7 or CF-8 – for gas loading experiments |
| OS-1 | 3He One shot fridge - designed for use in 11T magnet, can be used in Orange Cryostat |
0.5K-80K |
1 |
Echidna and Wombat (Powder Diffraction) Quokka (SANS) Taipan (3-Axis) Kowari (Strain Scanner) |
|
TB-1 TB-2 TB-3 |
|
-40C-250oC |
3 |
Quokka (SANS) |
|
F-1 |
RT-1800oC |
1 |
Echidna and Wombat (Powder Diffraction) Taipan (3-Axis). |
|
|
F-2 |
RT-1100oC |
1 |
Echidna and Wombat (Powder Diffraction) |
|
|
F-3 |
In Situ Reaction Chamber (Controlled Gas Furnace) (currently not available) |
RT-1500C |
1 |
Echidna and Wombat (Powder Diffraction) |
|
F-4 |
1000C Air Furnace for the Horizontal Load Frame
|
RT-1000C |
1 |
Kowari (Strain Scanner) |
|
P-1 |
(currently not available) |
200kN |
1 |
Echidna and Wombat (Powder Diffraction) |
|
P-2 |
|
100kN (tension or compression) |
1 |
Kowari (Strain Scanner) |
|
P-3 |
130 Tonne VX-5 Paris Edinburgh High Presure Cell
|
2GPa |
1 |
Echidna and Wombat (Powder Diffraction) |
|
P-4 |
Pressure Cells rated from 15 bar to 170 bar |
170 bar |
4 |
Echidna and Wombat (Powder Diffraction) Taipan and (3-Axis) |
|
VM-1 |
Vertical field cryomagnet / (CCR Cooled) |
B < 8T; T=4.2-300K |
1 |
Echidna and Wombat (Powder Diffraction) |
|
HM-1 |
Horizontal field cryomagnet (Lhe cooled)
|
B < 5T; 4K-300K |
1 |
Quokka (SANS) |
| HM-2 |
Horizontal field cryomagnet (Lhe cooled) |
B < 10T, (11T on request) |
1 |
Quokka (SANS) |
| HM-3 | Horizontal Field Electromagnet |
B <IT, 5K-300K |
1 |
Platypus |
| RQ-1 | Rapid Heat and Quench Cell |
150K-700K |
1 |
Quokka (SANS) |
|
RH-1 |
|
1 |
Quokka (SANS) |
|
|
SL-1 |
RT |
1 |
Platypus (Reflectometer) |
|
|
LF-1 LF-2 |
|
|
2 |
Platypus (Reflectometer) |
|
SC-1 |
SANS thermostat sample holders (ten position) |
RT-300oC |
1 |
Quokka (SANS) |
|
SC-2 |
|
-40°C-120°C |
1 |
Quokka (SANS) |
|
SC-3 |
Sealed multiple troughs (five position) |
|
1 |
Platypus (Reflectometer) |
|
SC-4 |
Sample changer-powders (one hundred position)
|
RT |
1 |
Echidna and Wombat (Powder Diffraction) |
|
EC-1 EC-2 |
|
10K-300K |
2 |
Echidna and Wombat (Powder Diffraction) |
| SP-1 | Syringe pump |
0.000073 mL/hr - 2100mL/hr |
1 |
Platypus (Reflectometer) |
| SF-1 | Stopped Flow Mixing Cell |
0.01ml |
1 |
Quokka (SANS) |
| AC-1 | AC Impedence Spectrometer |
10kOhm-100MOhm |
1 |
Platypus (Reflectometer) |
In general, the desired equipment (or desired range of Temperature, stress, magnetic field, etc.) should be specified in the original experiment proposal, and the sample environment equipment should be booked at the same time as the instrument booking.
|
Dr Paolo Imperia |
Mr Gene Davidson |
Mr Merv Perry |