MIBGen® Iobenguane - 123I - Injection Diagnostic

 

Product Information (PI)
Consumer Medical Information (CMI) 

 



Product Code
10007
IndicationsDiagnostic scintigraphic localisation of phaeochromocytomas, paragangliomas (chemodectomas), ganglioneuroblastomas and ganglioneuromas. Detection, staging and follow-up on therapy of neuroblastomas
Chemical Formmeta-Iodobenzyl (123I) Guanidine in Isotonic Phosphate buffer containing 1% v/v Benzyl Alcohol
pH4. 0 to 7.0
Radiochemical PurityNot less than 95% of the radioactivity of the chromatogram is found in the peak corresponding to iobenguane. Not more than 4% of the radioactivity is found in the peak corresponding to iodide and not more than 1% of the radioactivity is found on other peaks
Specific RadioactivityNot less than 10GBq of Iodine (I123) per gram of Iobenguane base
Radioactive Content2mL - 180 to 220 MBq at calibration
4mL - 360 to 440 MBq at calibration
Radioactive Concentration100 MBq Iodine (I-123) per mL (± 10%) at calibration
Calibration0900 hours Sydney time Tuesday
Pack Size200 MBq, 400MBq
AvailabilityMade to order - order by 1300 hours Sydney time Friday for delivery the following Tuesday 

Expiry

16 hours after calibration 
 Aust R101670